Sign In | Join Free | My portofva.com
China Shenzhen Huge Creation Technology Limited logo
Shenzhen Huge Creation Technology Limited
SHENZHEN HUGE CREATION TECHNOLOGY LIMITED Do us best for our customer better!
Active Member

12 Years

Home > Portable Patient Monitor >

PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor

Shenzhen Huge Creation Technology Limited
Contact Now

PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor

  • 1
  • 2

Place of Origin : guangdong

Brand Name : Huge

Certification : CE

Model Number : PM-60D

MOQ : 1

Price : 150-170USD

Packaging Details : Color Box

Delivery Time : within 1-3 days after payment confirmed

Payment Terms : Paypal, T/T, Western Union, MoneyGram

Supply Ability : 1000 per/month

function : Patient monitor

color : BLACK

gross weight : 1.5kg

warranty : one year

Contact Now

PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor

PM60D Patient Monitor is a portable device, designs with modularization, and can be freely combined for single-parameter or multi-parameter monitor. And it can be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.

PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor

Feature:

1.All-round monitoring for adult, pediatric and neonatal.
2.3.5'' (320×240) TFT LCD.
3.Operate with button and touch screen.
4.Review of data list and trend graph.
5.Configuring interface as user's requirements.
6.Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set.
7.Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
8.Selective SD card for storing 72-hour data.

Performance:

ECG
1.3-lead and 5-lead are optional.
2.Waveform display: dual-lead/full-lead
3.Gain selection: 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV
4.Measurement range for Heart rate(HR): 30bpm~300bpm, error: ±1bpm or ±1%, whichever is greater.
5.Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
6.Input current: ≤0.1μA
7.Enduring polarization voltage: ±300mV, sensitivity range: ±5%.
8.CMRR: filter mode(surgery, monitoring)≥80dB
9.Frequency response: 1~75Hz(+0.4dB,-3dB)
10.Low-frequency characteristic: time constant≥3.2s
11.Analysis function: heart rate, arrhythmia analysis, S-T segment analysis
12.S-T segment range: -2.0mV~2.0mV

Blood Pressure
1.Measurement method: Oscillometry

2.Measurement mode: manual/auto/continuous.
3.Auto measurement interval: adjustable from 1 to 90 minutes.
4.Resolution: 1mmHg.
5.Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
6.Self-check function.
7.Overpressure protection: double protection for software and hardware.
Range

Adult:
Systolic pressure: 40mmHg~270mmHg

Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg

Pediatric:
Systolic pressure: 40mmHg~200mmHg

Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg

Neonatal:
Systolic pressure: 40mmHg~135mmHg

Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
Upper and lower limit of alarm

SpO2 monitoring
1.Continuous real-time measuring.

2.Adopt digital SpO2 technology, which has strong anti-interference capability.
3.Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
4.Trend graph with the function of adaptive scaling
5.Standard finger-clip probe for adult , binding probe for neonatal is optional.

SpO2 Measuring
Range: 35%~100% (Resolution: 1%)

Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)

Accuracy: ±2bpm or ±2%, whichever is greater.

Measurement Performance in Weak Filling Condition:
SpO2 and Pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.

Resistance to surrounding light:

The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

Accessories
1.A power cord

2.A power adapter
3.An ECG lead wire
4.A SpO2 probe
5.An adult NIBP cuff
6.An extending tube for blood pressure

Physical characteristic of host
Dimension: 92(L)×22(W)×82(H)mm
Weight: 400g(including battery)


Product Tags:

quantum health analyzer

      

Quantum Health Test Machine

      
China PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor wholesale

PM60D ECG,Spo2,NIBP,PR portable handheld mini patient monitor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Huge Creation Technology Limited
*Subject:
*Message:
Characters Remaining: (0/3000)